VERIS INDUSTRIES H909 INSTALLATION MANUAL Pdf Download

您所在的位置:网站首页 dc user guide中文版 VERIS INDUSTRIES H909 INSTALLATION MANUAL Pdf Download

VERIS INDUSTRIES H909 INSTALLATION MANUAL Pdf Download

#VERIS INDUSTRIES H909 INSTALLATION MANUAL Pdf Download | 来源: 网络整理| 查看: 265

Advertisement

Quick Links Download this manual H909 Wiring ExamplE CONTACTOR Insulated Conductor Z201495-0B PAGE 1 Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris 'V' logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries. CURRENT MONITORING CONTROLLER Digital Input MOTOR Fan or Pump ©2009 Veris Industries USA 800.354.8556 or 503.598.4564 / [email protected] INSTALLATION GUIDE Split-Core Current Switch, Adjustable Trip Point, 120VAC/DC Output Installer's Specifications Sensor Power Insulation Class Frequency Range Temperature Range Humidity Range Amperage Range Output Hysteresis Off-State Leakage Safety Specification Note: For CE compliance, conductor shall be insulated according to IEC 61010‑1:2001, Installation Category III or equivalent. The product design provides for basic insulation only. quick install 1. Disconnect and lock out power to the conductor to be monitored. 2. Plan the installation: Locate a mounting surface for the removable mounting bracket that will allow the monitored conductor to pass through the iris, or "window" when it is installed and keep the product at least 1/2" (13mm) from any uninsulated conductors (CE). Determine cable routing for the controller connection, allowing wiring to reach the mounting location. 3. Install mounting bracket Drill holes to mount the bracket to the chosen surface using the included screws. 4. Wire the output connections between the sensor and the controller (solid-state contact). 5. Snap the sensor over the wire to be monitored and clip the assembly to the mounting bracket. 6. Calibrate the sensor (see page 2) with the load running normally. DimEnsions Removable Mounting Bracket 1.1" 0.8" (26 mm) (21 mm) 3.1" (79 mm) 2.8" (70 mm) Ø = 0.3" (8 mm) (64 mm) 3.0" (76 mm) 909 Induced from monitored current 600VAC rms (UL), 300VAC rms (CE) -15° to 60°C (5° to 140°F) 10-90% RH non-condensing 2.5 - 135A Continuous N.O. 200mA@120VAC/DC, polarity insensitive 10% of setpoint, typical UL 508, IEC 61010-1: 2001 CAT III 1.0" (25 mm) Bracket can be mounted on either side for added installation flexibility. Self-gripping Iris Use DIN Rail 1.4" Mounting clip (36 mm) (Veris part 2.5" number AH01) to mount on stan‑ dard DIN rail. 50/60Hz 1+ MΩ 05092 Previous Page Next Page 1 2

Advertisement



【本文地址】


今日新闻


推荐新闻


CopyRight 2018-2019 办公设备维修网 版权所有 豫ICP备15022753号-3